WiMAX360

Everything you need to know about WiMAX

Juliana Freitag Borin's Comments

Comment Wall (128 comments)

You need to be a member of WiMAX360 to add comments!

Join this Ning Network

At 11:12am on November 14, 2009, Talha Bin Fida said…
Hi Juliana
I am doing research on "Seamless mobility in Mobile WiMAX" and using NS-2 simulator with NIST WiMAX mobility package. I need your help regarding FMIPv6 patch for NS-2. If you have FMIPv6 patch or aware of any code that could be integrated into NS then please do let me know. I will highly thankful to you.
At 12:57pm on November 11, 2009, Flávio Alves Ferreira said…
Juliana consegui obter o valor razoavel da vazão do fluxo BE com a distribuição mixed, fazendo as alterações já citadas abaixo e alterando no script_vazao.sh o filtro do BE fazendo ... | grep http | ... ao invés de grep tcp.
Qualquer dica ou orientações novas são bem vindas.
Obrigado

Flávio Alves Ferreira
At 2:05pm on November 10, 2009, Flávio Alves Ferreira said…
Juliana alterei o valor máximo de acordo com aquele definido na referência "Changes in Web client access patterns: Characteristics and caching implications":

limitando o range de valores gerados pela distribuição lognormal em .../tools/rng.h:


double normal(double avg, double std);
inline double lognormal(double avg, double std) {
//return (exp (normal(avg, std)));
double valor = (exp (normal(avg, std)));
if ((valor) > 4092928)
return( 4092928);
else
return(valor);

Nesse documento ("Changes in Web client access patterns: Characteristics and caching implications") existem outros parâmetros, mostrados abaixo, além da média e desvio padrão quais além deles são necessários definir e como?

Statistic W98
Sample size 66,988
Minimum 1
Maximum 4,092,928
Mean 7,247
Median 2,416
Standard deviation 28,765
At 8:19am on November 10, 2009, Flávio Alves Ferreira said…
Complementando, se verificarmos o conteúdo de um dos arquivos de trace de uma das estações que utilizaram fluxo BE:

t: 0.745 sc: 1 tid: 1
t: 2.990 fc: 1 tid: 1 len: 1.7976900000000001e+298 dur: 2.245 act: 0
ERROR: Wrong throughtput 6.4066298389719704e+298
node: _o1307 t: 2.990 bw: 160165745974299263927315111305785225450391900475229744589160517875359909572035464451916131511579898686587032624823202187761915068743797022257807923619563985512819536913428926493529066647323437893570338038041546327348313271268569238095384136657339501432029860331389839051800818652968648704000000.000 throughput: 0.009 goodput: 0.009 rtt: 22.400000000000002 to: 0 cwnd: 3
At 8:08am on November 10, 2009, Flávio Alves Ferreira said…
Juliana,

a distribuição mixed definida no seu script de tfg.tcl apresenta valores de saída muito altos gerados pela distribuição lognormal com uma média de 7247 e desvio padrão de 28765. Quando solicito o cálculo da vazão das estações que usam fluxo BE é apresentado erro, pois a condição abaixo (tfg.tcl) é atendida:

if { $bw >= $bbw_ } {
puts $tracefilefd_ "ERROR: Wrong throughtput $bw"

$bbw_ foi definido como 40000000 e a vazão gerada a partir desses parâmetros de entrada apresenta um bw >> 40000000

Já limitei o range de valores gerados pela distribuição lognormal em .../tools/rng.h:


double normal(double avg, double std);
inline double lognormal(double avg, double std) {
//return (exp (normal(avg, std)));
double valor = (exp (normal(avg, std)));
if ((valor) > numeric_limits::max( )/1e10)
return(numeric_limits::max( )/1e10);
else
return(valor);

mas com esses valores altos de entrada da distribuição lognormal (7247 e 28765) a tendência é gerar valores extremamente elevados inicialmente e posteriormente caem, mas os valores muito altos estão inviabilizando os cálculos de vazão das estações com fluxo de serviço BE, você tem alguma sugestão para viabilizar isso utilizando os parâmetros de entrada que você definiu no seu artigo?
At 2:29pm on October 23, 2009, Flávio Alves Ferreira said…
Juliana,

Estou testando seu simulador para redes Wimax desenvolvido na plataforma do NS-2 e editei os scripts previamente encaminhados por você (example.tcl e mix-all.tcl), utilizando efetivamente o script “example.tcl” devidamente configurado com os parâmetros para criação de aplicações geradoras de tráfego que utilizam um fluxo de serviço específico definidos no script “mix-all.tcl”.

Meu objetivo é comparar os resultados obtidos e apresentados no artigo “Escalonamento com Qualidade de Serviço em redes IEEE 802.16” que foi aceito pelo SBRC 2007. Quando altero os parâmetros para simular o cenário 2 proposto, encontro o seguinte erro:

“Floating point exception”

que só ocorre quando as estações que foram criadas para trabalhar com BE são instanciadas, por isso seguem os parâmetros da aplicação definida para produzir um tráfego correspondente ao fluxo de serviço BE:

for {set j $be_init} {$j < $be_end} {incr j} {

set seed_index_ [expr $base_seed +$i]
incr i
set be_tfg_ul_($j) [new TrafficGen $ns_ $node_($j) $W $BW $be_rho $seed_index_ "traffigen$j.tr"]
$be_tfg_ul_($j) set dist_ mixed
$be_tfg_ul_($j) set body_dist_ 88
$be_tfg_ul_($j) set avg_len_b_ 7247
$be_tfg_ul_($j) set std_dev_ 28765
$be_tfg_ul_($j) set avg_len_t_ 10558.46
$be_tfg_ul_($j) set mshape_ 1.383
#configure TCP
$be_tfg_ul_($j) set tcp_flavor_ TCP/Reno
$be_tfg_ul_($j) set tcppsize_ 1000
$be_tfg_ul_($j) set windowsize_ 3000
$be_tfg_ul_($j) set ecnsupport_ 0
$be_tfg_ul_($j) set limittransmit_ 0

$be_tfg_ul_($j) set type_ 31

$be_tfg_ul_($j) start
}

Alguns desses parâmetros diferem daqueles parâmetros que você de fato utilizou para obter os resultados apresentados no artigo citado anteriormente? (De fato existem diversos parâmetros que não foram citados no artigo por isso estou inseguro em relação aos parâmetros citados anteriormente) Poderia revelar se esses valores correspondem ou se não, quais são os mais adequados?
At 6:20am on October 13, 2009, Denny Primadani Setianto said…
ok.. do u have the source code about wimax scheduling in ns2?
At 7:10pm on October 12, 2009, Denny Primadani Setianto said…
HI...nice to meet u
do u have source code in matlab about wimax scheduling?
thanks Juliana...

Denny
At 11:25am on October 8, 2009, darsh said…
Hi
thank you very much for reply ,
first : I try to change the routing protocol to DSDV or AODV , but when run the tcl script it give errors. i ckeck the site you wrote to me but cannot find NOAH extension for ns2.31. then check the ns2.31 and found directory called noah on it . so i think it support it ?
still the drop reason CBK exist !! have you any other idea

second: i try to work on the module which your group devolop ,
but when install ns2.28 on redhat EL5 , tcl8.4.5 give me error when configure (the error :checking system version (for dynamic loading) ./configure line:L7068: systax error
tcl 8.3.2 configuration failed)

is the operating system not support ns2.28??
can i solve this problem?
thank u july
At 2:32pm on October 7, 2009, darsh said…
hi
i install the bew patch for wimax module 2.6 from wimax forum on ns2.31
but when i try to run the sample scripts it give me drop entey in the out file
the source station send but at RTR there are drop due to CBR (call back router)
can u help me in this topic ??
another question , I try NDSL module but the output entries in outfile donot contain a unique identifier for the packet (like -Ii field in output entries). it is exist in the sending entry (started with s ), but 0 in received entries ??

plz help me

thank u
At 5:09pm on September 16, 2009, Jorge Moreira said…
Dr. Juliana:
Boa noite!
Conheci o seu módulo e fiquei bastante interessado em utilizá-lo para a minha tese porque tem implementado no módulo de Wimax, o QoS.
Porém a ideia que tenho para a tese é de construir uma ferramenta que ajude a dimensionar um acesso Wimax para clientes residenciais.
Ora a configuração que procuro fazer é representado pela imagem em anexo.
text2467.png

A questão é que os clientes residenciais teem determinados perfis de utilização da internet.
Essa ligação será condicionada pela ligação wimax do módulo e dimensionada de acordo com os clientes residenciais.
Cada SS (subscriber station) representa um cliente residencial (ou conjunto de clientes como num prédio habitacional). A linha de 1Gbps será para interligar os clientes (para o caso de um prédio habitacional).
Com isto pretendo medir os atrasos, débitos e pacotes perdidos.
Tenho uma questões a colocar:
- como agrego a ligação(link) de 1gbps a um nó SS? (era aqui neste link que iria efectuar medições de atrasos ,etc)
O tráfego que iria gerar seria no sentido download ou seja, da internet para as SS.
Será que me pode ajudar?


Obrigado!
Jorge Moreira
At 7:52am on September 7, 2009, darsh said…
hi juliana
I'm working in uplink scheduling algorithms in wimax
i install NIST module for wimax but as u know it is limited feature in scheduling
plz tell me where can find iwmax ns2 module support scheduling and an tcl axamples on it
my mail is " darsh_55@hotmail.com"
thank u
At 10:30pm on August 19, 2009, wee said…
hi juliana,
I'm currently working on the Wimax QoS based on your module. May i know how you get the average delay and throughput from the simulation. Is it extracted from the trace file, out.tr?If so, which type of packet, 802_16MAP or other else? i found that you have a number of functions in mac-802_16-bs.cc which will also generate some statistic, may i know what are these function about? Thanks
At 8:10pm on July 26, 2009, Oscar Rodriguez Avalos said…
http://rapidshare.com/files/260426529/salida.rar.html
At 8:08pm on July 26, 2009, Oscar Rodriguez Avalos said…
Hi Juliana im using your module for wimax.. and im already installed with the noah agent router... and i run the example.tcl ... but the output file "out.tr" is bad... i send you a direction to download the logs of the simulation.. maybe i have wrong parameters in the $ ns example.tcl 4 ... ????

At 7:19am on June 29, 2009, salum said…
hello julliana

i am a security student and i have to do a simulation about wimax showing on security issues. i have choosed Wimax. what do you think about it. and do you wich opnet version i could use. please i need a help from you people. i will apreciate ur help sister.
thank you and tc
At 3:50pm on June 16, 2009, Zafarullah Bhutto said…
I am an RF Engineer with v. good experience in WIMAX & RF & IBS design & Planning, looking for new opportunity related to RF or IBS, location wise no any issue even AFRICA region. Have look on my profile or contact me zafar_telecom@hotmail.com
At 9:56pm on May 13, 2009, MARCIO ANDREY TEIXEIRA said…
Olá Juliana, tudo bem ?
Seu novo aqui no Wimax360. Sou aluno de doutorado da Universidade Federal de Uberlândia. Minha tese está focada em Escalonamento de pacotes uplink e também com gerenciamento de polliging Unicast adaptativo. Li os seus trabalhos e gostei muito. Se você puder, futuramente gostaria de tirar algumas dúvidas com você, caso tenha disponibilidade.
Abraços,
Márcio.
At 6:43am on May 1, 2009, Faheem said…
Dear Dr. Juliana,

I am doing my project resarch on "Rate control and scheduling for transmission to multiple users through WiMAX. I have been told by my supervisior, to resarch on each scheduling techniques such as,RoundRobin,PF and other techniques. By collecting each data such as Packet loss, Throughput, Delay packets. Due to this i having problems comparing a data and then making a spreadsheet graph. Are there any particular journal avaliable or online simulations tools avaliable so that i can use as my part resarch and reference.

Thanks for all your help really appreciated.
At 12:49pm on April 30, 2009, Hassan Naqvi said…
Dear Dr. Juliana,

I remember last time when i scraped you, you were just a student, b ut now i must congrat you on your PHD degree.
Hey, i need some advanced topics on WiMAX MAC layer and QOS. I am working on a commercial WiMAX network and we are in the process of implementing LLC on our network, i guess a strng theoretical base of QOS will be helpful. Looking forward.

Regards,
Hassan Naqvi
meditranian@gmail.com

WiMAX360 Guidelines

Badge

Loading…

© 2010   Created by WiMAX Broadband Solutions

Badges  |  Report an Issue  |  Privacy  |  Terms of Service